Contact us

Certification

Reaction to fire

The fire reaction of construction products is determined on the basis of harmonized test methods and is classified according to the European standard EN 13501-1. In this list corresponding classification is stated :
 

  • JI Vulcasteel Roof and JI Vulcasteel Wall:
    • 50 to 200 mm: A2-s1,d0 (rapport No. RA10-0429)
  • ​​JI Roof:
    • 40 to 150 mm: B-s2,d0, PIR (rapport No. 14510E)
  • JI Wall PIR :
    • 40 to 200 mm: B-s2,d0 , PIR (rapport No. 14662G)
  • JI Wall VB:
    • 60 to 150 mm: B-s2,d0, PIR (rapport No. 14662G)
  • JI Onduroof:
    • 40 to 60 mm: B-s2,d0, PIR (rapport No. 14510E) 
  • JI Permapan:
    • 40 to 100 mm:  B-s2,d0, PIR (rapport No. 14471E)

Fire resistance

The fire resistance of a construction product is determined on the basis of harmonized test methods and is classified according to the European standard EN 13501-2 . The classification is expressed in minutes . In this list corresponding classification is stated :

  • JI Vulcasteel Roof :
    • 80 mm: REI 60 (rapport No. C0011)
    • 120 mm: REI 120 (rapport No. C0009)
  • JI Vulcasteel Wall :
    • 80 mm, vertical assembly: EI 60 (rapport No. 2011-Efectis-R0449)
    • 100 mm, vertical assembly: EI 90 (rapport No. C0007)
    • 100 mm, perfo-inner sheet, vertical assembly: EI 60 (rapport No. C0006) 
    • 120 mm, vertical assembly: EI 120 (rapport No. 2011-Efectis-R0451)
    • 120 mm, horizontal assembly: EI 180 (rapport No. C0008) 
    • 180 mm, vertical assembly: EI 240 (rapport No. C0005)
  • JI Vulcasteel Wall 1000SF :
    • 100 mm, vertical assembly: EI 60 (rapport No. C0010/ 2011-Efectis-R0450)
  • JI Roof PIR :
    • 40 mm, PIR: RE 60 (rapport No. 2005-CVB-R0479)
    • 60 mm, PIR : REI 20 / RE 30 (rapport No. 2011-Efectis-R0023)
    • 60 mm, PIR : RE 120 (evaluation No. 2011-Efectis-R0022)
    • 60 mm, as a wall application with PIR foam :
      • EI 15/ EW 120 (rapport No. 2005-CVB-R0478)
    • 100 mm, PIR, vertical assembly: EI 30 / EW30 (rapport No. 12695A)
    • 200 mm, PIR, vertical assembly: EI 60/ EW 120 (rapport No. 13191C)
  • JI Wall 1000SF:
    • 60 mm, PIR, vertical assembly:
      • EI 20/ EW60 (rapport No. 2010-Efectis-R0543)
    • 80 mm, PIR, vertical assembly:
      • EI 20/ EW30 (rapport No. 2010-Efectis-R0788)
    • 80 mm, PIR, vertical assembly:
      • EI 20-ef/ EW60-ef (rapport No. 2011-Efectis-R0101)
    • 100 mm, PIR, vertical assembly:
      • EI 30/ EW 60 (rapport No. 2006-CVB-R0388)

Above classifications are valid , subject to compliance with the corresponding installation instructions .


 

Production control

 

Overview

ISO 9001

(Click on image to view certificate)
Assessed to ISO 9001
Cert/LPCB ref. 700

ISO 14001

(Click on image to view certificate)
Assessed to ISO 14001
Cert/LPCB ref. 700-EMS

OHSAS 18001

(Click on image to view certificate)

Assessed to OHSAS 18001
Cert/LPCB ref. 700-HS

LPS 1181

(Click on image to view certificate)
LPS 1181 Cert/LPCB ref. 700a

LPS 1208

(doorklikken op het logo)

LPS 1208 Cert/LPCB ref. 700d