JI Roof PIR

Roof Panels

The JI Roof PIR LPCB certified Trapezoidal Insulated Roof Panel is used for pitched roofs or horizontal and vertical wall application and an external insulated cladding panel for industrial, commercial and public buildings. Due to its metal inner and outer sheet, it combines thermal resistance with big spans. The minimum pitch to be applied is 4° or more after deflection.

JI Roof PIR

Specifications of JI Roof PIR

Solutions

Dimensions

Length:
Min. 2000.0mm/ max. 13500.0mm
Width:
Min. 1000.0mm/ max. 1000.0mm

Thickness & weight

40 mm:
11.71 kg/m²
60 mm:
12.51 kg/m²
80 mm:
13.3 kg/m²
100 mm:
14.1 kg/m²
120 mm:
14.89 kg/m²
150 mm:
16.09 kg/m²
JI Roof PIR

Characteristics

Material: S 320 GD

Basic coating for outdoor applications (clad-ding, roofing and accessories, air conditioners)

16_UK
Leathergain plastisol suitable for roof and wall cladding systems where good performance is required at a competitive price. 17_UK
External uses in severe environments: profiles, sandwich panels for roofing and cladding, building materials (tiles, guttering etc). 18_UK

HPS200 Ultra® has been developed to perform in demanding environments – both external and internal.

02

Reference standards

Galvanized steel:
EN 10346
Coil coating:
EN 10169
Tolerance:
EN 10143
Calculations:
EN 14509

Insulation

Core:
Polyisocyanurate (PIR) foam
Fire resistance:
Up to E65/EI15
Fire classification :
B-s1, d0

Insulation table

Insulation table Thickness U (W/m²K) Rw (dB)
40.0 0.53 24.0
60.0 0.36 24.0
80.0 0.25 25.0
100.0 0.2 26.0
120.0 0.17 26.0
150.0 0.14 27.0