Specifications of JI Vulcasteel Wall 1000SF (Liner profile)
Solutions
Dimensions
- Length:
- Min. 2500.0mm/ max. 14000.0mm
- Width:
- Max. 1000.0mm
Thickness & weight
- 60 mm:
- 16.71 kg/m²
- 80 mm:
- 18.71 kg/m²
- 100 mm:
- 20.71 kg/m²
- 120 mm:
- 22.7 kg/m²
- 150 mm:
- 25.7 kg/m²
- 175 mm:
- 28.2 kg/m²
- 200 mm:
- 30.7 kg/m²
- 240 mm:
- 34.69 kg/m²
Characteristics
- Material:
- Steel S280 GD
Essential (25 µ)
Basic coating for outdoor applications (cladding, roofing and accessories, air conditioners)
Ultra
External uses in severe environments: profiles, sandwich panels for roofing and cladding, building materials (tiles, guttering etc)
Ultra-X
The Ultra 75 coating is the most durable coating for roofing and cladding. It is the best alternative to PVC-plastisol paints to improve the performance of building systems and it contributes to the CO2 reduction at project level.
Reference standards
- Galvanized steel:
- EN 10346:2015 - tolerances according to EN 10143:2006
- Coil coating:
- EN 10169:2022
- Tolerance:
- EN 14509:2013 (Geometry)
- Calculations:
- EN 14509:2013
Insulation
- Core:
- Mineral Fiber core
- Fire classification :
- A2-s1,d0 (for all coatings except HPS 200 Ultra) according to EN 13501-1:2019
Insulation table
| Insulation table Thickness (mm) | U (W/m²K) | R (m².K/W) | Ei (minutes) | ||
|---|---|---|---|---|---|
| 60.0 | 0.71 | 1.4 | - | - | - |
| 80.0 | 0.54 | 1.85 | - | - | - |
| 100.0 | 0.43 | 2.3 | 60.0 | (i<->o) | vert |
| 120.0 | 0.36 | 2.75 | 60.0 | (i<->o) | vert |
| 150.0 | 0.29 | 3.45 | 60.0 | (i<->o) | hor / vert |
| 175.0 | 0.25 | 4.0 | 60.0 | (i<->o) | hor / vert |
| 200.0 | 0.21 | 4.65 | 120.0 | (i<->o) | vert |
| 240.0 | 0.18 | 5.5 | 120.0 | (i<->o) | vert |