Specifications of JI Eco 1000 60-100
Solutions
Dimensions
- Length:
- Min. 2500.0mm/ max. 13500.0mm
- Width:
- Max. 1000.0mm
Thickness & weight
- 60 mm:
- 8.34 kg/m²
- 100 mm:
- 9.86 kg/m²
Characteristics
- Material:
- Steel S280 GD
Essential (25 µ)
Basic coating for outdoor applications (cladding, roofing and accessories, air conditioners)
HPS 200 Ultra®
HPS200 Ultra has been developed to perform in demanding environments – both external and internal.
Ultra-X (70-75 µ)
The Ultra 75 coating is the most durable coating for roofing and cladding. It is the best alternative to PVC-plastisol paints to improve the performance of building systems and it contributes to the CO2 reduction at project level.
Ultra 60
External uses in severe environments: profiles, sandwich panels for roofing and cladding, building materials (tiles, guttering etc)
Reference standards
- Galvanized steel:
- EN 10346:2015 - tolerances according to EN 10143:2006
- Coil coating:
- EN 10169:2022
- Tolerance:
- EN 14509:2013 (Geometry)
- Calculations:
- Flat-rate application of EN 14509:2013
Insulation
- Core:
- Polyisocyanurate (PIR), density: 40 ± 5 kg/m³, without CFC-HCFC
- Fire classification :
- B-s2,d0 according to EN 13501-1:2019
Insulation table
Insulation table Thickness (mm) | U (W/m²K) |
---|---|
60.0 | 0.34 |
100.0 | 0.21 |