Specifications of JI Roof 1000
Solutions
Dimensions
- Length:
- Min. 2550.0mm/ max. 20500.0mm
- Width:
- Max. 1000.0mm
Thickness & weight
- 30 mm:
- 10.38 kg/m²
- 40 mm:
- 10.76 kg/m²
- 60 mm:
- 11.52 kg/m²
- 80 mm:
- 12.28 kg/m²
- 100 mm:
- 13.04 kg/m²
- 120 mm:
- 13.78 kg/m²
- 130 mm:
- 14.17 kg/m²
- 150 mm:
- 14.94 kg/m²
![JI Roof 1000](https://api.clfyj5-jorisiden1-p1-public.model-t.cc.commerce.ondemand.com/medias/JRI-JI-Roof-PIR-TVI-AB-PID-003-515Wx515H.jpeg?context=bWFzdGVyfHJvb3R8NjI2MnxpbWFnZS9qcGVnfGFEWmtMMmczWVM4NE9UWXhOakUyT1RNMk9Ua3dMMHBTU1Y5S1NWOVNiMjltWDFCSlVsOVVWa2xmUVVKZlVFbEVYekF3TTE4MU1UVlhlRFV4TlVndWFuQmxad3wyM2ZkNmRkZGI3ZTRmOGYzYzExMzY1NjMxODc2OTIyYjk5MTM5ODYzYTc3ZGY3YWNkMmI3OTFmNWRmYTFkNDYx)
Characteristics
- Material:
- Steel S280 GD
Essential (25 µ)
Basic coating for outdoor applications (cladding, roofing and accessories, air conditioners)
![PE25](https://api.clfyj5-jorisiden1-p1-public.model-t.cc.commerce.ondemand.com/medias/JRI-Cloudy-Durable-Essential-Grandemat-Ultra-3D-EN-1200Wx1200H.jpg?context=bWFzdGVyfHJvb3R8NDQwNDV8aW1hZ2UvanBlZ3xhR0UwTDJobE55ODRPVEExTmpVMU1UZzVOVE0wTDBwU1NWOURiRzkxWkhrdFJIVnlZV0pzWlMxRmMzTmxiblJwWVd3dFIzSmhibVJsYldGMExWVnNkSEpoWHpORVgwVk9YekV5TURCWGVERXlNREJJTG1wd1p3fGExMWQ4Y2E3YmFjMTk5MmIwMTYyMGU3MTAxOTU4YTk2ZjFjNGIwYjMzNDA1N2ZhZDllMGQ5ZjVkM2ZlYmQ3Y2E)
Ultra 60
External uses in severe environments: profiles, sandwich panels for roofing and cladding, building materials (tiles, guttering etc)
![PUR60](https://api.clfyj5-jorisiden1-p1-public.model-t.cc.commerce.ondemand.com/medias/JRI-Cloudy-Durable-Essential-Grandemat-Ultra-3D-EN-1200Wx1200H.jpg?context=bWFzdGVyfHJvb3R8NDQwNDV8aW1hZ2UvanBlZ3xhR0UwTDJobE55ODRPVEExTmpVMU1UZzVOVE0wTDBwU1NWOURiRzkxWkhrdFJIVnlZV0pzWlMxRmMzTmxiblJwWVd3dFIzSmhibVJsYldGMExWVnNkSEpoWHpORVgwVk9YekV5TURCWGVERXlNREJJTG1wd1p3fGExMWQ4Y2E3YmFjMTk5MmIwMTYyMGU3MTAxOTU4YTk2ZjFjNGIwYjMzNDA1N2ZhZDllMGQ5ZjVkM2ZlYmQ3Y2E)
Ultra 75
The Ultra 75 coating is the most durable coating for roofing and cladding. It is the best alternative to PVC-plastisol paints to improve the performance of building systems and it contributes to the CO2 reduction at project level.
![PUR75](https://api.clfyj5-jorisiden1-p1-public.model-t.cc.commerce.ondemand.com/medias/JRI-Coatings-Ultra-X-Theme-1200Wx1200H.jpg?context=bWFzdGVyfHJvb3R8NDcxMzd8aW1hZ2UvanBlZ3xhRGt3TDJobVl5ODRPVFUwTURFeE5URTJPVFU0TDBwU1NWOURiMkYwYVc1bmMxOVZiSFJ5WVMxWVgxUm9aVzFsWHpFeU1EQlhlREV5TURCSUxtcHdad3xiOWE0N2Y1YTZmYTBjODgyOGMxMDYzYzMwZDllZGM1NDc5MTJiODliZjQyNGVlNmY0MTNmMTVkN2YxMGYyZjE3)
HPS 200 Ultra®
HPS200 Ultra has been developed to perform in demanding environments – both external and internal.
![PS200H](https://api.clfyj5-jorisiden1-p1-public.model-t.cc.commerce.ondemand.com/medias/JRI-HPS-200-Ultra-3D-EN-1200Wx1200H.jpg?context=bWFzdGVyfHJvb3R8NTE2NzJ8aW1hZ2UvanBlZ3xhRFE1TDJnelpTODRPVEExTmpVM016VXlNakl5TDBwU1NWOUlVRk10TWpBd0xWVnNkSEpoWHpORVgwVk9YekV5TURCWGVERXlNREJJTG1wd1p3fGMxNmRiNTUwYTQ1MTcyNjEyYzY3OGYzMDQyNDQ2OWQ2YTcxM2E1NTNkODc1ZTI0MzkwZDQ0NmQwY2MwY2RlYzE)
Reference standards
- Galvanized steel:
- EN 10346:2015 - tolerances according to EN 10143:2006
- Coil coating:
- EN 10169:2022
- Tolerance:
- EN 14509:2013 (Geometry)
- Calculations:
- EN 14509:2013
Insulation
- Core:
- Polyisocyanurate (PIR)
- Fire classification :
- B-s2,d0 according to EN 13501-1:2019
Insulation table
Insulation table Thickness (mm) | U (W/m²K) | Rw (dB) |
---|---|---|
30.0 | 0.65 | 24.0 |
40.0 | 0.5 | 24.0 |
60.0 | 0.34 | 24.0 |
80.0 | 0.25 | 25.0 |
100.0 | 0.2 | 26.0 |
120.0 | 0.17 | 26.0 |
130.0 | 0.16 | 26.0 |
150.0 | 0.14 | 27.0 |