Specifications of JI Vulcasteel Roof 37-500
Solutions
Dimensions
- Length:
- Min. 2500.0mm/ max. 13600.0mm
- Width:
- Max. 1000.0mm
Thickness & weight
- 60 mm:
- 16.16 kg/m²
- 120 mm:
- 22.15 kg/m²
- 200 mm:
- 30.14 kg/m²

Characteristics
- Material:
- Steel S280 GD
Essential (25 µ)
Basic coating for outdoor applications (cladding, roofing and accessories, air conditioners)

Ultra 60
External uses in severe environments: profiles, sandwich panels for roofing and cladding, building materials (tiles, guttering etc)

Ultra 75
The Ultra 75 coating is the most durable coating for roofing and cladding. It is the best alternative to PVC-plastisol paints to improve the performance of building systems and it contributes to the CO2 reduction at project level.

Reference standards
- Galvanized steel:
- EN 10346:2015 - tolerances according to EN 10143:2006
- Coil coating:
- EN 10169:2022
- Tolerance:
- EN 14509:2013 (Geometry)
- Calculations:
- EN 14509:2013
Insulation
- Core:
- Mineral Fiber core
Insulation table
Insulation table Thickness (mm) | U (W/m²K) | R (m².K/W) |
---|---|---|
60.0 | 0.68 | 1.45 |
120.0 | 0.35 | 2.8 |
200.0 | 0.22 | 4.6 |