Specifications of JI Vulcasteel Roof 37-500
Solutions
Dimensions
- Length:
- Min. 2500.0mm/ max. 13600.0mm
- Width:
- Max. 1000.0mm
Thickness & weight
- 50 mm:
- 15.16 kg/m²
- 60 mm:
- 16.16 kg/m²
- 80 mm:
- 18.16 kg/m²
- 100 mm:
- 20.15 kg/m²
- 120 mm:
- 22.15 kg/m²
- 150 mm:
- 25.17 kg/m²
- 175 mm:
- 27.69 kg/m²
- 200 mm:
- 30.14 kg/m²
Characteristics
- Material:
- Steel S280 GD
Essential (25 µ)
Basic coating for outdoor applications (cladding, roofing and accessories, air conditioners)
Ultra-X (70-75 µ)
The Ultra 75 coating is the most durable coating for roofing and cladding. It is the best alternative to PVC-plastisol paints to improve the performance of building systems and it contributes to the CO2 reduction at project level.
Ultra 60
External uses in severe environments: profiles, sandwich panels for roofing and cladding, building materials (tiles, guttering etc)
Reference standards
- Galvanized steel:
- EN 10346:2015 - tolerances according to EN 10143:2006
- Coil coating:
- EN 10169:2022
- Tolerance:
- EN 14509:2013 (Geometry)
- Calculations:
- EN 14509:2013
Insulation
- Core:
- Mineral Fiber core
- Fire classification :
- A2-s1,d0 (for all coatings except HPS 200 Ultra) according to EN 13501-1:2019
Insulation table
Insulation table Thickness (mm) | U (W/m²K) | R (m².K/W) |
---|---|---|
50.0 | 0.8 | 1.2 |
60.0 | 0.68 | 1.45 |
80.0 | 0.52 | 1.9 |
100.0 | 0.42 | 2.35 |
120.0 | 0.35 | 2.8 |
150.0 | 0.29 | 3.5 |
175.0 | 0.25 | 4.05 |
200.0 | 0.22 | 4.6 |